outerdiameter.com

ASTM F876/F877 (CTS) · chart

ASTM F876/F877 (CTS) PEX tubing chart — outer diameter and wall thickness

Crosslinked polyethylene tubing in CTS (copper tube size) ODs, designated by SDR rather than schedule. This table covers 9 nominal sizes from CTS 1/4 to CTS 2. It gives the outside of the pipe and every wall we publish for it; the bore each wall leaves is on that size's own page.

Nominal sizes
9
Published wall values
3
Wall series
1
OD range
9.5–54 mm
Wall thickness in inches — millimetre version below
NominalDNOD (in)9
1/480.375—
3/8100.500—
1/2150.6250.070
5/8—0.750—
3/4200.8750.097
1251.1250.125
1 1/4321.375—
1 1/2401.625—
2502.125—
Wall thickness in millimetres (derived from the inch value × 25.4)
NominalDNOD (mm)9
1/489.525—
3/81012.700—
1/21515.8751.778
5/8—19.050—
3/42022.2252.464
12528.5753.175
1 1/43234.925—
1 1/24041.275—
25053.975—

Report a wrong value

How to read this table

Size pages

Each size has its own page with the wall series side by side, bore in both units, DN and sources:

CTS 1/4 · CTS 3/8 · CTS 1/2 · CTS 5/8 · CTS 3/4 · CTS 1 · CTS 1 1/4 · CTS 1 1/2 · CTS 2

Same nominal, other materials

ASME B36.10M (welded and seamless steel pipe) · ASTM D2241 (PVC pressure pipe) · ASME B36.19M (stainless steel pipe)

Edition not captured. The numbers are confirmed by two independent published sources, but we have not verified which printing of ASTM F876/F877 (CTS) they came from, so no year is claimed here.How values are verified and what is still open.